|   Spring Hanger SHD | 
                   Formatwork 
                   Applicable | 
                   Deck plate/Slab with an insulation mat placed | 
                 
                
                  |  Use | 
                   For light gage steel frames and heavy equipment | 
                 
                
                  |  Type | 
                   Spring type | 
                 
              
             
             | 
          
          
            
             
             | 
          
          
            |   | 
          
          
            
            
              
                
                  
                  
                    
                      
                          | 
                        
                        
                          
                            
                               | 
                             
                            
                              
                               
                               | 
                             
                            
                              Developed for the slab with an insulation mat placed. 
Suitable for the insulation with thickness of 25 mm and 50 mm. 
                              A spring is used to fix the insert.The insert will not be tipped even 
                              @if stomped. 
                              Easy installation only by pressing the insert by hand into the drilled 
                              @hole etc. 
Color can be checked from top and bottom of the deck plate. 
Insured with product liability insurance | 
                             
                            
                              |   | 
                             
                            
                              | Use[Spring Hanger SHZ] for the slab with fire resistant coating. | 
                             
                            
                              | Embedded depth in concrete can be changed with L-type used. | 
                             
                          
                         
                         | 
                       
                    
                   
                   | 
                 
                
                  |   | 
                 
              
             
             | 
          
          
            
            
              
                
                  
                  
                    
                      
                        |  Part No.List-Code No.M10077 Spring Hanger SHD | 
                        Pullout test values are values when the insert breaks | 
                        Unit:mm | 
                       
                    
                   
                   | 
                 
                
                  
                  
                          
                      
                        | Part No. | 
                        Thread 
                        size | 
                        Effective 
Embedded 
Depth(mm) | 
                         Insulation 
Thickness 
(mm) | 
                        Drill 
                        Diameter 
(mm) | 
                        Embedded in Concrete,Pullout 
Test Result | 
                        Quantity/ 
Case(pcs) | 
                        Color | 
                        Effetive Thread Length S | 
                        Diameter of Head 
c | 
                        Diameter of Core 
 | 
                        Height 
g | 
                        Thickness of Head 
 | 
                        Insulation Layer 
` | 
                       
                      
                        Ave. 
Pullout Force(kN) | 
                        Concrete Compressive Strength(N/mm2) | 
                       
                      
                        | SHD-3025 | 
                        W3/8 | 
                        32.5 | 
                        25 | 
                        16.0 | 
                        14.6 | 
                        17.6 | 
                        200 | 
                        
                        
                         | 
                        13 | 
                        22 | 
                        12 | 
                        35 | 
                        2.5 | 
                        25 | 
                       
                            
                        | SHD-3025L | 
                        W3/8 | 
                        42.5 | 
                        25 | 
                        16.0 | 
                        20.9 | 
                        23.6 | 
                        200 | 
                        
                        
                         | 
                        13 | 
                        22 | 
                        12 | 
                        45 | 
                        2.5 | 
                        25 | 
                       
                      
                        | SHD-3050 | 
                        W3/8 | 
                        47.5 | 
                        50 | 
                        16.0 | 
                        26.0 | 
                        26.2 | 
                        150 | 
                        
                        
                         | 
                        13 | 
                        22 | 
                        12 | 
                        50 | 
                        2.5 | 
                        50 | 
                       
                      
                        | SHD-4025 | 
                        W1/2 | 
                        46 | 
                        25 | 
                        22.0 | 
                        33.1 | 
                        18.6 | 
                        100 | 
                        
                        
                         | 
                        25 | 
                        28 | 
                        17 | 
                        50 | 
                        4 | 
                        25 | 
                       
                      
                        | SHD-4025L | 
                        W1/2 | 
                        56 | 
                        25 | 
                        22.0 | 
                        38.6 | 
                        28.0 | 
                        100 | 
                        
                        
                         | 
                        25 | 
                        28 | 
                        17 | 
                        60 | 
                        4 | 
                        25 | 
                       
                      
                        | SHD-4050 | 
                        W1/2 | 
                        46 | 
                        50 | 
                        22.0 | 
                        33.1 | 
                        18.6 | 
                        100 | 
                        
                        
                         | 
                        25 | 
                        28 | 
                        17 | 
                        50 | 
                        4 | 
                        50 | 
                       
                      
                        | SHD-5025L | 
                        W5/8 | 
                        100 | 
                        25 | 
                        28.0 | 
                        60.9 | 
                        16.3 | 
                        50 | 
                        
                        
                         | 
                        30 | 
                        38 | 
                        22 | 
                        105 | 
                        5 | 
                        25 | 
                       
                      
                        | SHD-5050 | 
                        W5/8 | 
                        75 | 
                        50 | 
                        28.0 | 
                        61.1 | 
                        24.1 | 
                        50 | 
                        
                        
                         | 
                        30 | 
                        38 | 
                        22 | 
                        80 | 
                        5 | 
                        50 | 
                       
                      
                        | SHD-M1025 | 
                        M10 | 
                        52.5 | 
                        25 | 
                        17.0 | 
                        26.8 | 
                        23.6 | 
                        200 | 
                        
                        
                         | 
                        13 | 
                        22 | 
                        13 | 
                        55 | 
                        2.5 | 
                        25 | 
                       
                      
                        | SHD-M1225 | 
                        M12 | 
                        46 | 
                        25 | 
                        22.0 | 
                        33.1 | 
                        18.6 | 
                        100 | 
                        
                        
                         | 
                        25 | 
                        28 | 
                        17 | 
                        50 | 
                        4 | 
                        25 | 
                       
                    
                         
                   | 
                 
                
                  |   | 
                  Items in square brackets are the set available upon order. | 
                 
              
             
             | 
          
          
            |  Placement Procedure | 
          
          
            
            
              
                
                  
                  
                    
                      
                          | 
                       
                      
                        1.Open a hole into an insulation using a Slidart punch. 
                        2.Cut a hole at the marked position on the deck plate 
                          precisely using a drill or hole saw of the specified 
                          diameter (see for boring tools.) 
                        3.Easy installation by pressing the insert lightly into the hole 
                          by hand. 
4.Screw in a bolt to the full depth to prevent loosening. | 
                       
                    
                   
                   | 
                    | 
                 
              
             
             | 
          
          
            |   | 
          
          
            
             
             |