| Color | 
                  
                  
                   | 
                  Click the appointed color. | 
                 
              
             
            
             | 
             | 
            
            
              
                
                  | Features | 
                 
                
                  
                   
                   | 
                 
                
                  ●A spring is used to fix the insert. The insert will not be 
                   tipped even if stomped. 
                  ●Easy installation only by pressing the insert by hand into 
                   the drilled hole etc. 
                  ●Color can be checked from the top and bottom of the 
                   deck plate. 
                  ●Suitable for hanging lightweight items like electrical and 
                    disaster prevention systems | 
                 
                
                  |   | 
                 
                
                  | 
                  
                   | 
                 
              
             
             | 
          
          
            |   | 
          
          
            
            
              
                
                  | Part No.List-Code No.M10069 Keystone-man | 
                    *Pullout test values are values when the insert breaks | 
                    Unit: mm | 
                 
              
             
             | 
          
          
            
            
              
                
                  | Part No. | 
                  Thread size | 
                  Effective 
                  Embedded 
                  Depth(mm) | 
                  Drill 
                  Diameter 
                  (mm) | 
                  Embedded in Concrete, Pullout Test Result | 
                  Quantity/ 
                  Case 
                  (pcs) | 
                  Color | 
                  Effective 
                  Thread 
                  Length S | 
                  Diameter  
                  of Head 
                  D | 
                  Diameter 
                  of Core 
                  d | 
                  Height 
                  H | 
                  Thickness 
                  of Head 
                  h | 
                 
                
                  Ave. 
                  Pullout Force(kN) | 
                  Concrete 
                  Compressive 
                  Strength(N/mm2) | 
                 
                
                  | KM-3030 | 
                  W3/8 | 
                  32.5 | 
                  16.0 | 
                  14.6 | 
                  17.6 | 
                  300 | 
                  RD・BL・YL・WT・GR 【PK VT】 | 
                  13 | 
                  22 | 
                  12 | 
                  35 | 
                  2.5 | 
                 
              
             
             | 
          
          
            
            
              
                
                  |   | 
                   Items in square brackets are the set available upon order.  | 
                 
              
             
             | 
          
          
            |   | 
          
          
            | Placement Procedure | 
             | 
             | 
          
          
            
            
            
              
                
                  1.Cut a hole at the marked position precisely using a drill or hole saw
                  of the specified diameter(boring tools) 
                  2.Place the insert into the hole. 
                  3.Easy installation by pressing the insert lightly into the hole. 
                  4.Screw in a bolt to the full depth to prevent loosening. | 
                 
              
             
             | 
             | 
            
            
             |